양액재배관련제품
  • 6단변온 온도 콘트롤러 HT-1000
  • Model HT-1000
    Dealer High Tech
    Manufacturer DONGWOO Co., Ltd.
    Controller Microprocessor
    (automatic control depending on the setting by user).
    Analog Input Temperature sensor 2 areas (Mini shelter)
    Digital output 2 areas(control of circulation pump, hot air blower)
    Power source AC220V / 60Hz
  • HP-3100 이미지
  • Features
    of the
    system
    • To be controlled by 6-steps of time/temperature setting
    • Control of circulation pump/3-way valve, hot air blower
    • Precise temperature setting & temperature sensing (setting by 0.1 degree)
    • Average temperature report per stage during past 30 days
    • Temperature sensor gives warning signal against high/low temperature
    • Time setting for increasing/decreasing temperature
    • On-the-spot output test can be made
  • 하이테크 HT-1500 사용자 설명서
  • [ Setting example to be reviewed by graph ]

    Setting for 1st area - setting temperature for ventilation : 24,
                                          setting temperature for heating : 23℃,
                                          60 minutes for increasing time (starting to control during daytime)


    Setting for 2nd area - setting temperature for ventilation : 26℃,
                                          setting temperature for heating : 23℃,
                                          60 minutes for increasing time (area to be controlled during daytime)


    Setting for 3rd area - setting temperature for ventilation : 28℃,
                                          setting temperature for heating : 23℃,
                                          60 minutes for increasing time (area to becontrolled during daytime)


    Setting for 4th area - setting temperature for ventilation : 19℃,
                                           setting temperature for heating : 18℃,
                                           60 minutes for decreasing time(area to be induced for generative growth)


    Setting for 5th area - setting temperature for ventilation : 21℃,
                                           setting temperature for heating : 20℃,
                                           60 minutes for increasing time(starting to control during nighttime)


    Setting for 6th area - setting temperature for ventilation : 21℃,
                                           setting temperature for heating : 120℃,
                                           60 minutes for decreasing time(area to be controlled during nighttime)


    ⓐ Setting temperature increasing area from previous area(6th area) to the 1st area(starting to control during daytime)

    ⓑ Setting temperature decreasing area from previous area(3rd area) to the 4th area(starting to control during nighttime)

    ⓒ Setting temperature maintaining for 4th area

    * Generally, increasing and decreasing time is set in between 30∼60 minutes.
    * 60 minutes of increasing time for 1℃ and 30 minutes of decreasing time for 1℃ may applicable to suit crop physiology.